Título: Avaliação de gordura corporal pela bioimpedância elétrica e sua correlação com diferentes pontos anatômicos de medida da circunferência da cintura em crianças
Autor(es): Sant' Anna, Mônica de Souza Lima
Tinoco, Adelson Luiz Araújo
Rosado, Lina Enriqueta F. P. de Lima
Sant’Ana, Luciana Ferreira da Rocha
Mello, Amanda de Carvalho
Brito, Igor Surian de Sousa
Araújo, Larissa Fortunato
Santos, Tássia Ferreira
Abstract: Comparar os diferentes pontos anatômicos de medida da circunferência da cintura, bem como a eficácia desses locais em predizer o percentual de gordura corporal mensurado pela bioimpedância elétrica tetrapolar. Foram avaliadas 205 crianças de 6 a 9 anos de idade de ambos os sexos. Foram coletados dados de peso, estatura e circunferência da cintura em três locais diferentes: na menor curvatura abdominal, sobre a cicatriz umbilical e no ponto médio entre a última costela e crista ilíaca. A avaliação do estado nutricional foi realizada a partir do índice de massa corporal/idade recomendado pela Organização Mundial de Saúde. No presente estudo houve homogeneidade entre os sexos, e a idade média foi de 7,2±1,2 anos. Em relação ao estado nutricional, 6,3% das crianças apresentaram baixo peso, 75,1% eram eutróficas, 7,3% apresentaram sobrepeso e 11,2% obesidade. No sexo masculino não houve diferença estatística entre os diferentes locais de medida. No feminino, a medida sobre a cicatriz umbilical foi estatisticamente maior. Na análise de correlação, a circunferência medida no ponto médio foi a que obteve melhor correlação com o percentual de gordura corporal, com valores de 0,50 nos meninos e 0,62 nas meninas. A circunferência da cintura medida no ponto médio entre a crista ilíaca e ultima costela foi a que apresentou melhor correlação com o percentual de gordura corporal.
To compare the different anatomical sites used in the measurement of waist circumference, as well as the effectiveness of these landmarks to predict the percentage of body fat by tetrapolar bioelectrical impedance analysis. We evaluated 205 children from 6 to 9 years of age of both sexes. Data on weight, height and waist circumference were collected at three different sites: at the lower abdominal curvature, above the navel and at the midpoint between the last rib and the iliac crest. Nutritional status was assessed through the body mass index (BMI)/age as recommended by the World Health Organization. The sample was considered homogeneous in terms of sex, and the mean age was 7.2±1.2 years. Regarding nutritional status, 6.3% of the children had low weight, 75.1% were eutrophic, 7.3% were overweight, and 11.2% were obese. Among males, there was no statistical difference between the different sites of measurement; in females, the measurement above the navel was statistically higher. In the correlation analysis, the midpoint measurement showed the best correlation with percentage of body fat, with values of 0.50 in boys and 0.62 in girls.Waist circumference measured at the midpoint between the last rib and the iliac crest presented the best correlation with percentage of body fat.
Editor: Jornal de Pediatria
Tipo de Acesso: Sociedade Brasileira de Pediatria
URI: http://dx.doi.org/10.2223/JPED.1871
http://www.locus.ufv.br/handle/123456789/19648
Data do documento: 17-Dez-2008
Aparece nas coleções:Artigos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
artigo.pdf
  Until 2100-12-31
texto completo146,08 kBAdobe PDFVisualizar/Abrir ACESSO RESTRITO


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.