Use este identificador para citar ou linkar para este item: https://locus.ufv.br//handle/123456789/25345
Tipo: Artigo
Título: Efeito da taxa de carregamento sobre a remoção de poluentes de esgoto em sistemas alagados construídos
Autor(es): Matos, Antonio T. de
Brasil, Mozart da S.
Lo Monaco, Paola A. V.
Abstract: Objetivou-se estudar o efeito da taxa de carregamento sobre a eficiência de sistemas alagados, construídos de escoamento horizontal subsuperficial (SAC-EHSS), em remover poluentes de esgoto sanitário. Os SAC-EHSS foram alimentados com efluente proveniente de tanque séptico, sob taxas de carregamento orgânico volumétrico (TCOV) de 53 a 231 g m-3d-1 de demanda química de oxigênio (DQO total) e as associadas taxas de carregamento (TCV) de demanda química de oxigênio solúvel, sólidos suspensos totais (SST), nitrogênio total (N-Total) e fósforo total (P-Total). Para avaliação de desempenho dos SAC-EHSS, as mesmas variáveis foram quantificadas em seu efluente. Relação linear e positiva foi obtida entre as taxas de remoção de DQO total, DQO solúvel e SST, e as TCV, nas faixas em que foram aplicadas, além de não terem sido observados efeitos negativos desta variável sobre a eficiência na remoção desses poluentes. As taxas de remoção de N-Total e P-Total não apresentaram, entretanto, tendência de aumento com a TCV aplicada nos SAC- EHSS, cultivados com taboa e utilizados no tratamento de efluente sanitário. As cargas aplicadas desses nutrientes devem ser consideradas referenciais no dimensionamento desses sistemas, caso se queira maximizar a remoção global de poluentes da água residuária.
This research aimed to study the effect of loading rate on the efficiency of constructed wetlands with horizontal subsurface flow (CW-HSSF) to remove pollutants from wastewater. The CW-HSSF were fed with effluent from septic tank under volumetric organic loading rate (OLRV) of 53 to 231 g m-3d-1 of chemical oxygen demand (total-COD) and associated loading rates (LRV) of soluble chemical oxygen demand (soluble COD), total suspended solids (TSS), total nitrogen (total-N) and total phosphorus (total-P). To evaluate the performance of CW-HSSF the same variables were quantified in its effluent. Linear and positive relationship was found between the removal rates of total COD, soluble COD and TSS and the LRV, within the application range, and no negative effects on this variable in removal efficiencies of these pollutants. The removal rate of total-N and total-P did not show, however, tendency to increase with the LRV applied in the CW-HSSF planted with cattail and used in treating sanitary sewage. The loads applied of these nutrients must be considered referential in sizing these systems, if desired to maximize the overall removal of wastewater pollutants.
Palavras-chave: Carga orgânica
Sistemas wetland
Tratamento biológico
Organic load
Wetland systems
Biological treatment
Editor: Engenharia Agrícola
Tipo de Acesso: Open Access
URI: http://dx.doi.org/10.1590/S0100-69162013000200011
http://www.locus.ufv.br/handle/123456789/25345
Data do documento: Mar-2013
Aparece nas coleções:Engenharia Agrícola - Artigos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
artigo.pdfTexto completo312,43 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.