Use este identificador para citar ou linkar para este item:
https://locus.ufv.br//handle/123456789/5106
Tipo: | Dissertação |
Título: | Compósito de hidroxiapatita sintética e lignina como promotor de osseointegração entre implante metálico e tecido ósseo: estudo experimental em cães |
Título(s) alternativo(s): | Hydroxyapatite-lignin composite as a metallic implant-bone tissue osseointegration improver: experimental study in dogs |
Autor(es): | Santos, Letícia Corrêa |
Primeiro Orientador: | Borges, Andrea Pacheco Batista |
Primeiro coorientador: | Silva, João Carlos Pereira da |
Segundo coorientador: | Carlo, Ricardo Junqueira Del |
Primeiro avaliador: | Reis, Alexandre Martins |
Segundo avaliador: | Reis, Emily Correna Carlo |
Abstract: | O objetivo do presente trabalho foi o de avaliar o compósito HAP-91-L®, formado por hidroxiapatita sintética (20%) e lignina (80%) como promotor de integração entre implante metálico e tecido ósseo. Ambos os membros pélvicos de 15 cães foram submetidos ao procedimento cirúrgico experimental, determinados MT (membro tratado) e MC (membro controle). Através de um orifício na face proximal lateral das tíbias foi retirada medula óssea, que acrescida ao compósito, foi recolocada no canal medular, com posterior implantação do pino intramedular de Schanz no MT. No MC a medula foi triturada com a posterior colocação do pino. Foram realizadas avaliações clínicas durante 15 dias para deiscência, claudicação, sensibilidade dolorosa e edema. Radiografias foram realizadas imediatamente após o procedimento, e nos 8, 60 e 150 dias subsequentes. Nas mesmas datas, exceto no dia da cirurgia, os animais foram eutanasiados para avaliação macroscópica das tíbias e coleta de material para histologia. Não foram observadas deiscência e infecção local. Ocorreu diferença entre MT e MC para claudicação, sensibilidade dolorosa e edema indicando leve reação inflamatória local no MT. Radiograficamente e macroscopicamente não foram observadas reações periosteais ou osteolíticas em nenhuma das tíbias avaliadas. Conclui-se que o compósito testado é biocompatível e osteocondutor. The objective of this study was to evaluate the composite PAH-91-L ®, formed by synthetic hydroxyapatite (20%) and lignin (80%) as a promoter of integration between metal implant and bone tissue. Both hind limbs of 15 dogs were subjected to experimental surgical procedure, referred as MT (treated limb) and MC (control limb). The bone marrow was removed through an orifice of the lateral proximal tibia, which after added to the composite was replaced in the medullary canal with subsequent implantation of the intramedullary Schanz pin in the MT. In MC the marrow was triturated with subsequent placing of the pin. Clinical evaluations were performed for 15 days to assess dehiscence, lameness, pain and edema. Radiographs were taken immediately after the procedure, and in the following 8, 60 and 150 days. On the same dates, except on the surgery day, the animals were euthanized for macroscopic evaluation of the tibia and to collect material for histology. Dehiscence or local infections were not observed. There were differences between MT and MC for lameness, pain and edema indicating mild local inflammatory reaction in MT. Radiographically and macroscopically there were no osteolytic or periosteal reactions in none of the evaluated tibias. It was concluded that the compound tested is biocompatible and osteoconductive. |
Palavras-chave: | Regeneração óssea Resistência mecânica Reparação óssea Bone regeneration Mechanical resistance Bone repair |
CNPq: | CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA |
Idioma: | por |
País: | BR |
Editor: | Universidade Federal de Viçosa |
Sigla da Instituição: | UFV |
Departamento: | Biotecnologia, diagnóstico e controle de doenças; Epidemiologia e controle de qualidade de prod. de |
Citação: | SANTOS, Letícia Corrêa. Hydroxyapatite-lignin composite as a metallic implant-bone tissue osseointegration improver: experimental study in dogs. 2012. 60 f. Dissertação (Mestrado em Biotecnologia, diagnóstico e controle de doenças; Epidemiologia e controle de qualidade de prod. de) - Universidade Federal de Viçosa, Viçosa, 2012. |
Tipo de Acesso: | Acesso Aberto |
URI: | http://locus.ufv.br/handle/123456789/5106 |
Data do documento: | 3-Abr-2012 |
Aparece nas coleções: | Medicina Veterinária |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
texto completo.pdf | 1,1 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.