Use este identificador para citar ou linkar para este item: https://locus.ufv.br//handle/123456789/12655
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorRocha, Keller Sullivan Oliveira
dc.contributor.authorMartins, José Helvecio
dc.contributor.authorMartins, Marcio Arêdes
dc.contributor.authorTinôco, Ilda de Fátima Ferreira
dc.contributor.authorSaraz, Jairo Alexander Osorio
dc.contributor.authorLacerda Filho, Adílio Flauzino
dc.contributor.authorFernandes, Luiz Henrique Martins
dc.date.accessioned2017-10-31T17:50:31Z
dc.date.available2017-10-31T17:50:31Z
dc.date.issued2014-05-22
dc.identifier.issn1932-6203
dc.identifier.urihttps://doi.org/10.1371/journal.pone.0095874
dc.identifier.urihttp://www.locus.ufv.br/handle/123456789/12655
dc.description.abstractBased on the necessity for enclosure protection of temperature and relative humidity sensors installed in a hostile environment, a wind tunnel was used to quantify the time that the sensors take to reach equilibrium in the environmental conditions to which they are exposed. Two treatments were used: (1) sensors with polyvinyl chloride (PVC) enclosure protection, and (2) sensors with no enclosure protection. The primary objective of this study was to develop and validate a 3-D computational fluid dynamics (CFD) model for analyzing the temperature and relative humidity distribution in a wind tunnel using sensors with PVC enclosure protection and sensors with no enclosure protection. A CFD simulation model was developed to describe the temperature distribution and the physics of mass transfer related to the airflow relative humidity. The first results demonstrate the applicability of the simulation. For verification, a sensor device was successfully assembled and tested in an environment that was optimized to ensure fast change conditions. The quantification setup presented in this paper is thus considered to be adequate for testing different materials and morphologies for enclosure protection. The results show that the boundary layer flow regime has a significant impact on the heat flux distribution. The results indicate that the CFD technique is a powerful tool which provides a detailed description of the flow and temperature fields as well as the time that the relative humidity takes to reach equilibrium with the environment in which the sensors are inserted.en
dc.formatpdfpt-BR
dc.language.isoengpt-BR
dc.publisherPlos Onept-BR
dc.relation.ispartofseriesVolume 9, Issue 5, e95874, May 2014pt-BR
dc.rightsOpen Accesspt-BR
dc.subjectSensorspt-BR
dc.subjectModeling and simulationpt-BR
dc.titleModeling and simulation of the transient response of temperature and relative humidity sensors with and without Protective housingen
dc.typeArtigopt-BR
Aparece nas coleções:Engenharia Agrícola - Artigos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
10.1371%2Fjournal.pone.0095874.PDFtexto completo4,25 MBAdobe PDFThumbnail
Visualizar/Abrir