dc.identifier.citationLIMA, Júnia Cápua de. Occurrence of Staphylococcus sp. in the hospital environment, surface characterization and Staphylococcus aureus adhesion to polyurethane and silicone nasoenteral tubes. 2007. 163 f. Dissertação (Mestrado em Ciência de Alimentos; Tecnologia de Alimentos; Engenharia de Alimentos) - Universidade Federal de Viçosa, Viçosa, 2007.por
dc.identifier.urihttp://locus.ufv.br/handle/123456789/2827-
dc.description.abstractEspécies de Staphylococcus foram isoladas e identificadas de dietas enterais, do ar do ambiente de Centro de Terapia Intensiva (CTI) e da sala de preparo de nutrição enteral, de manipuladores da sonda e da dieta, de superfícies de preparo, da mucosa nasal de pacientes e de sondas nasoenterais de poliuretanos e silicone após uso em ambientes de um hospital municipal. Os isolados foram identificados utilizando-se o kit API Staph da BioMérieux®. Avaliou-se a sensibilidade dos isolados a antimicrobianos pelo método de discos impregnados com antibióticos das seguintes substâncias: ciprofloxacina- CIP (5 µg), amicacina-AMI (30 µg), clindamicina-CLI (2 µg), claritromicina-CLA (15 µg), ceftriaxona-CRO (30 µg), ceftazidima-CAZ (30 µg), imipenem-IMP (10 µg), oxacilina- OXA (1 µg), sultamicilina ampicilina e sulbactam-APS (10/10 µg) e vancomicina-VAN (30 µg). Corpos-de-provas das sondas de poliuretano e silicone foram submetidos à análise de tensão de ruptura e estiramento (equipamento Instron), à análise da hidrofobicidade das superfícies internas pelo método do ângulo de contato (aparelho goniômetro) e da rugosidade e topografia pela técnica da microscopia de força atômica. A adesão de um isolado de Staphylococcus aureus nas superfícies internas das sondas foi avaliada por contagem- padrão em placa e por microscopia eletrônica de varredura. Foram constatadas altas contagens de Staphylococcus sp. no ar do CTI (2,15 ± 0,36 log UFC.m-3), na sala de preparo da dieta (1,64 ± 0,17 log UFC.m-3) e nas sondas após uso (entre 6,88 log UFC.cm-2 e 7,38 log UFC.cm-2). S. aureus foi a espécie mais freqüente dentre os isolados (52,44%), estando presente em maior porcentagem em sondas nasoenterais (28,05%). Quarenta e quatro isolados, entre 48 analisados, foram sensíveis ao antibiótico carbapenêmico imipenem, o que correspondeu a 91,6%, e 1 isolado foi sensível ao glicopeptídeo vancomicina (2,1%). No entanto, 47 (87,5%) isolados foram resistentes ao antimicrobiano ceftazidima da classe das cefalosporina (cefens). A sonda de poliuretano foi mais resistente do que a de silicone nos testes de tensão de ruptura e estiramento e mostrou-se hidrofílica (Ow = 50,2 ± 0,61), enquanto a de silicone, hidrofóbica (Ow = 74,6 ± 1,30). O poliuretano apresentou maior rugosidade média do que o silicone, com rugosidade média (Ra) de 2,87 nm, e a diferença máxima entre o ponto mais alto e o mais baixo (Rt) foi de 53,90 nm. Observou-se a ocorrência de irregularidades, como protuberâncias, fissuras, fendas e orifícios nas fotomicrografias das superfícies. Por meio da análise microscópica, constatou-se que S. aureus foi capaz de aderir em ambas as superfícies. As médias das contagens de S. aureus aderidos, após três dias de teste, não diferiram (p>0,05) e atingiram 1,11 log UFC.cm-2 para poliuretano e 0,99 log UFC.cm-2 para silicone. A importância dos diversos fatores envolvidos na aderência dos microrganismos às superfícies ainda deve ser melhor e mais claramente estabelecida. A utilização de modelos que simulem a contaminação bacteriana dos polímeros é muito importante para o seu aperfeiçoamento. Novos polímeros devem ser pesquisados e testados na fabricação de sondas nasoenterais com o intuito de reduzir ou impedir a adesão bacteriana, por meio da modificação das características físicoquímicas da superfície.pt_BR
dc.description.abstractStaphylococcus species were isolated and identified from enteral diets, ambient air from the Intensive Care Unit (ICU) and from the enteral nutrition preparation room, handlers of feeding tubes and diets, preparation surfaces, patient s nasal mucous and polyurethane and silicone nasoenteral tubes used in rooms of a municipal hospital. The isolates were identified using the API Staph kit (BioMérieux®, France). Sensibility of isolates to antimicrobial agents was evaluated by the detection method using paper discs impregnated with the following antibiotics: ciprofloxacin-CIP (5 µg), amikacin-AMI (30 µg), clindamycin-CLI (2 µg), clarithromycin-clar (15 µg), ceftriaxone-CRO (30 µg), ceftazidime-CAZ (30 µg), imipenem- IMP (10 µg), oxacylin-OXA (1 µg), sultamicillin- ampicillin and sulbactam-APS (10/10 µg) and vancomycin-Van (30 µg). Specimens of polyurethane and silicone tubes were analyzed for rupture tension and stretching (Instron Testing Machine), hydrophobicity analysis of internal surfaces by contact angle measurement (goniometer) and surface roughness and topography by atomic force microscopy. Adhesion of Staphylococcus aureus isolates to tube internal surfaces was evaluated by standard plate count and scanning electron microscopy. High Staphylococcus sp counts were confirmed in the ICU air (2.15 ± 0.36 log UFC.m-3), in the diet preparation room (1.64 ± 0.17 log UFC.m-3) and in the used tubes (between 6.88 log UFC.cm-2 and 7.38 log UFC.cm-2). S. aureus was the most frequent species amongst the isolates (52.44%), with the largest percentage in nasoenteral tubes (28.05%). Among 48 isolates analyzed, 44 were sensitive to imipenem, a carbapenemic antibiotic, corresponding to 91.6%, and one isolate was sensitive to the glycopeptide vancomycin (2.1%). However, 47 (87.5%) isolates were resistant to the antimicrobial ceftazidime, in the cephalosporin class (cephens). The polyurethane tube was more resistant than the silicone one in the rupture tension and stretching tests and was shown hydrophilic (Ow = 50.2 ± 0.61), whereas the silicone tube was hydrophobic (Ow = 74.6 ± 1.30). The polyurethane tube showed higher mean surface roughness than the silicone one, with mean roughness (Ra) of 2.87 nm, with maximum difference between the highest and the lowest point (Rt) of 53.90 nm. There was occurrence of irregularities such as protuberances, fissures, rifts and holes on the surface photomicrographies. The microscopic analysis showed that S. aureus was capable to adhere to both surfaces. After three days of tests, S. aureus mean counts were not different (p>0.05), reaching 1.11 log UFC.cm-2 for polyurethane and 0.99 log UFC.cm-2 for silicone. The importance of the several factors involved in microorganism adherence to surfaces still has to be better and more clearly established. The use of models simulating bacterial contamination of polymers is crucial for new developments. New polymers should be researched and tested for the production of nasoenteral tubes in order to reduce or inhibit bacterial adhesion by modifying physicochemical surface characteristics.eng
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Federal de Viçosapor
dc.rightsAcesso Abertopor
dc.subjectAdesão bacterianapor
dc.subjectStaphylococcus spp.por
dc.subjectSondas nasoenteraispor
dc.subjectBacterial adhesioneng
dc.subjectStaphylococcus spp.eng
dc.subjectNasoenteral tubeseng
dc.titleOcorrência de Staphylococcus sp. em ambiente hospitalar, caracterização de superfícies e adesão de Staphylococcus aureus em sondas nasoenterais de poliuretano e siliconepor
dc.title.alternativeOccurrence of Staphylococcus sp. in the hospital environment, surface characterization and Staphylococcus aureus adhesion to polyurethane and silicone nasoenteral tubeseng
dc.typeDissertaçãopor
dc.contributor.authorLatteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4779295P3por
dc.contributor.advisor-co1Carvalho, Antônio Fernandes de
dc.contributor.advisor-co1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781655T2por
dc.contributor.advisor-co2Soares, Nilda de Fatima Ferreira
dc.contributor.advisor-co2LattesSOARES, N. F. F.por
dc.publisher.countryBRpor
dc.publisher.departmentCiência de Alimentos; Tecnologia de Alimentos; Engenharia de Alimentospor
dc.publisher.programMestrado em Ciência e Tecnologia de Alimentospor
dc.publisher.initialsUFVpor
dc.subject.cnpqCNPQ::CIENCIAS AGRARIAS::CIENCIA E TECNOLOGIA DE ALIMENTOS::CIENCIA DE ALIMENTOS::MICROBIOLOGIA DE ALIMENTOSpor
dc.contributor.advisor1Andrade, Nélio José de
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4788281Y5por
dc.contributor.referee1Coimbra, Jane Sélia dos Reis
dc.contributor.referee1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4798752J6por
dc.contributor.referee2Mendonça, Regina Célia Santos
dc.contributor.referee2Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4790986E3por
dc.contributor.referee3Pinto, Cláudia Lúcia de Oliveira
dc.contributor.referee3Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783521J6por
Aparece nas coleções:Ciência e Tecnologia de Alimentos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
texto completo.pdf2,79 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.