Use este identificador para citar ou linkar para este item: https://locus.ufv.br//handle/123456789/788
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFonseca, Sandra Parreiras Pereira
dc.date.accessioned2015-03-26T12:31:36Z-
dc.date.available2007-07-11
dc.date.available2015-03-26T12:31:36Z-
dc.date.issued2007-02-28
dc.identifier.citationFONSECA, Sandra Parreiras Pereira. Evaluation of a sewage treatment plant overland flow method. 2007. 144 f. Tese (Doutorado em Construções rurais e ambiência; Energia na agricultura; Mecanização agrícola; Processamento de produ) - Universidade Federal de Viçosa, Viçosa, 2007.por
dc.identifier.urihttp://locus.ufv.br/handle/123456789/788-
dc.description.abstractO objetivo do presente trabalho foi avaliar o desempenho da unidade de tratamento de esgoto doméstico (ETE), constituída por desarenador, tanque de equalização, tanque séptico e tratamento secundário por disposição no solo pelo método do escoamento superficial nas condições edafoclimáticas do município de Viçosa, MG, implantada em um CAMBISSOLO Háplico Tb distrófico latossólico, textura argilo-arenosa. Foram implantados quatro planos de sistematização, cada um com três faixas de 1 m de largura, 25 m de comprimento e declividade de 2%, cultivadas com o capim Tifton 85 bermudagrass (Cynodon spp.). Foi aplicada a taxa de 0,48 m3.h-1.m-1 por um período de dez horas e freqüência de seis dias por semana, durante seis meses de operação. Foram coletadas amostras do esgoto a cada 2 m do início da faixa até atingir 18 metros, 10 minutos após a chegada do afluente ao ponto de coleta, duas vezes por semana, as quais foram submetidas às análises físicas, químicas e de contagem de coliformes. Após seis meses de operação do sistema, amostras do solo e da vegetação foram coletadas e submetidas às análises físicas e químicas. O pH do esgoto tendeu a aumentar ao longo da faixa de tratamento e a CE e as concentrações de DBO, DQO, N total, P total e K, a reduzir-se. Já a tendência da concentração de Na foi manter-se constante ao longo da faixa. Os teores de matéria seca (MS), proteína bruta (PB), N, P e K da matéria verde do capim Tifton 85 tenderam a reduzir-se ao longo do comprimento da faixa de tratamento. Na camada de 0-10 cm do solo ocorreu aumento do pH e da CEes e das concentrações de MO, N-total, P-disponível, Na e K trocáveis; entretanto, com a aplicação do esgoto esse aumento tendeu a ser menor ao longo do comprimento da faixa. Na camada de 50-60 cm, as concentrações de MO e N-total se mantiveram constantes. Já o pH, a CEes, o P-disponível, o Na e o K trocáveis tenderam a reduzir-se, na camada de 50-60 cm, ao longo da faixa de tratamento. A concentração de Na e K trocáveis aumentou no perfil do solo. Não houve variação na população de coliformes totais e fecais (E. coli) ao longo da faixa de tratamento; por essa razão, esses indicadores microbiológicos não devem ser usados para avaliação do desempenho de ETE por escoamento superficial. O modelo do EPA 1984, quando ajustado aos dados experimentais, representou adequadamente a remoção de DBO e DQO, entretanto os coeficientes K e K diferiram dos encontrados por outros autores em diferentes condições edafoclimáticas, tipos de efluente tratado e taxas de aplicações.pt_BR
dc.description.abstractThe objective of the present work was to evaluate the performance of a sewage treatment unit (ETE), constituted of sand box, equalization tank, septic tank and overland flow system, under the edafoclimatic conditions of Viçosa, MG, implanted in a Dystrudepts, with a clayey-sandy texture. The plant area was land leveled in four plans, each one with three borders of 1 m width, 25 m length with 2% of slope, and cultivated with Tifton 85 grass bermudagrass (Cynodon spp.). The application rate of 0,48 m3.h-1.m-1 was applied for ten hours a day and six day a week, during six months of operation. The samples of sewage collected along the borders, at every 2 meters up to 18 meters, were submitted to physical, chemical and coliforms analyses and after six months physical and chemical analyses were carried out in the soil and vegetation samples. The sewage pH tended to increase along the border, and the CE, the DBO, DQO, N-total, P-total and K+ concentrations tended to decrease. The Na concentration tended to remain constant along the border. The amounts of dry matter (DM), crude protein (CP), N, P and K of the grass Tifton 85 green matter tended to decrease along the length of the border. In the 0-10 cm layer of the soil there was an increase in the pH, CEes, OM, N-total, P-available, and the concentrations of K and Na exchangeable, however, with the sewage application, the increase was less along of the border. In the 50-60 cm layer the OM and N-total in the soil remained constant. The pH, CEes, P-available, Na and K tended to decrease along the border in the 50-60 cm layer. The exchangeable Na and K increased in the soil profile. The total and fecal coliforms - E. coli population remain practically constant along the border. These microorganisms are not recommended for the monitoring of ETE by disposal on the soil. The EPA model proposed in 1984 represented well the removal of the DBO and DQO, however the coefficients K and K differed from those observed by other authors under different edafoclimatic conditions, kind of effluent treated and application rates.eng
dc.description.sponsorship
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Federal de Viçosapor
dc.rightsAcesso Abertopor
dc.subjectEsgotospor
dc.subjectEscoamento superficialpor
dc.subjectColiformespor
dc.subjectModelagempor
dc.subjectSewageeng
dc.subjectOverland floweng
dc.subjectColiformseng
dc.titleAvaliação de uma estação de tratamento de esgoto doméstico por escoamento superficialpor
dc.title.alternativeEvaluation of a sewage treatment plant overland flow methodeng
dc.typeTesepor
dc.contributor.authorLatteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4758952P4por
dc.contributor.advisor-co1Matos, Antonio Teixeira de
dc.contributor.advisor-co1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783529H2por
dc.publisher.countryBRpor
dc.publisher.departmentConstruções rurais e ambiência; Energia na agricultura; Mecanização agrícola; Processamento de produpor
dc.publisher.programDoutorado em Engenharia Agrícolapor
dc.publisher.initialsUFVpor
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::TRATAMENTO DE AGUAS DE ABASTECIMENTO E RESIDUARIASpor
dc.contributor.advisor1Soares, Antonio Alves
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787014Z2por
dc.contributor.referee1Ramos, Márcio Mota
dc.contributor.referee1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783666U8por
dc.contributor.referee2Azevedo, Mônica de Abreu
dc.contributor.referee2Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782410Z5por
dc.contributor.referee3Vianna, Marcos Rocha
dc.contributor.referee3Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783795A4por
Aparece nas coleções:Engenharia Agrícola

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
texto completo.pdf893,86 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.