dc.identifier.citationDOMINGOS, Cintia Ataliba. Proposing guidelines for the implementation of sustainable and energy efficient solutions in buildings of the Federal University of Viçosa/MG. 2010. 66 f. Dissertação (Mestrado em Geotecnia; Saneamento ambiental) - Universidade Federal de Viçosa, Viçosa, 2010.por
dc.identifier.urihttp://locus.ufv.br/handle/123456789/3753-
dc.description.abstractOs novos edifícios, decorrentes da expansão física da UFV podem ocasionar impactos, principalmente quanto à demanda energética. Considerando-se essa perspectiva, é importante para a UFV adequar os projetos para que os edifícios sejam energeticamente eficientes quando postos em uso. Para tanto, é necessário avaliar e classificar a eficiência energética dos edifícios ainda na etapa de projeto, para que as adequações necessárias sejam feitas antes da execução do edifício. Nesse sentido, o objetivo geral deste trabalho é propor diretrizes para a implementação de soluções energeticamente eficientes e sustentáveis em edifícios do Campus da UFV/Viçosa. Como objeto de estudo tomou-se o Edifício da Saúde, que faz parte das obras do REUNI/UFV que se encontra em processo de execução no Campus UFV/Viçosa desde setembro de 2009. A avaliação e classificação deste edifício foram realizadas utilizando-se o Método Prescritivo de Etiquetagem, que consiste em uma classificação dos requisitos relativos ao desempenho de três partes do edifício: a envoltória, o sistema de iluminação e o sistema de condicionamento do ar. Por meio deste trabalho pode-se observar que a Etiquetagem e Classificação de Edifícios é uma eficiente técnica para avaliar consumo energético de edificações e, se incorporada à rotina de elaboração de projetos de obras para os campi da UFV, contribuirá para a minimização dos custos de energia e para um desempenho mais sustentável da infra-estrutura desta instituição, além de se constituir num importante referencial para a sociedade.pt_BR
dc.description.abstractThe new buildings, resulting from physical expansion of the UFV can cause impacts, particularly regarding energy demand. Seen from this perspective it is important to tailor projects to UFV that buildings are energy efficient when put into use. Therefore, it is necessary to evaluate and rate the energy efficiency of buildings still in desing stage so that necessary adjustments are made before the execution of the building. Thus, the aim of this paper is to propose guidelines for the implementation of sustainable and nergy efficient solutions in buildings in the Campus of UFV/Viçosa. As the object of study hás become the Building Health, part of the works of REUNI/UFV that is in the process of implementing the Campus UFV/Viçosa since September 2009. The evaluation and classification of this building were performed using the Prescribed Method of tagging, which is a classifiction of perfomance requirements of the building of the three parts: the envelope, the lighting system anda ir conditioning system. Though this work can be seen that the Classification and Labellign of Buildins is na efficient technique to avaluate energy consumption of building and, if incorporated into the routine of preparing for construction work for the Campus UFV/Viçosa, contribute to the minimization of costs energy and performance for a more sustainable infrastructure of this instituition, and constitue na important benchmark for society.eng
dc.description.sponsorship
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Federal de Viçosapor
dc.rightsAcesso Abertopor
dc.subjectEficiência energéticapor
dc.subjectSoluções energéticaspor
dc.subjectSoluções sustentáveispor
dc.subjectEnergy efficienteng
dc.subjectEnergy solutionseng
dc.subjectSustainable solutionseng
dc.titleProposição de diretrizes para a implementação de soluções energeticamente eficientes e sustentáveis em edifícios da Universidade Federal de Viçosa/MGpor
dc.title.alternativeProposing guidelines for the implementation of sustainable and energy efficient solutions in buildings of the Federal University of Viçosa/MGeng
dc.typeDissertaçãopor
dc.contributor.authorLatteshttp://lattes.cnpq.br/4839090043630427por
dc.contributor.advisor-co1Lustoza, Regina Esteves
dc.contributor.advisor-co1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4709152H2por
dc.contributor.advisor-co2Gonçalves, Wantuelfer
dc.contributor.advisor-co2Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4785438Z8por
dc.publisher.countryBRpor
dc.publisher.departmentGeotecnia; Saneamento ambientalpor
dc.publisher.programMestrado em Engenharia Civilpor
dc.publisher.initialsUFVpor
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL::PROCESSOS CONSTRUTIVOSpor
dc.contributor.advisor1Tibiriçá, Antônio Cleber Gonçalves
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4794527Y8por
dc.contributor.referee1Paes, José Luiz Rangel
dc.contributor.referee1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4766675E6por
dc.contributor.referee2Jentzsch, Rolf
dc.contributor.referee2Latteshttp://lattes.cnpq.br/1336424717049685por
Aparece nas coleções:Engenharia Civil

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
texto completo.pdf3,32 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.